Flowmeter Products

Filters applied: rpeat: Repeatability4 [x]

Displaying 32 results

spacer
LF15
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 90 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
MF30
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 180 litres per hour 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF4
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.

  • 0 to 400 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF8
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.Hazardous area approved as standard.

  • 0 to 800 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LF03
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

  • 0 to 18 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF20
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 1200 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF40
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 2400 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF66
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard. Special order only.

  • 0 to 4000 l/hr 
  • +/-1% reading - linearity.
  • +/-0.25% repeatability.

More Information

Open PDF
V270
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium, PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 16,500 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LMGN
     
Pick

Low cost, plastic bodied Pelton Wheel flowmeter with push-on hose connections, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.006 to 0.1 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMSPFA
         
    Pick

    Pelton Wheel flowmeter with 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid up to 40 bar pressure.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMX series
         
    Pick

    Inline Pelton Wheel flowmeter with integral flow straighteners, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min and higher.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMSS
         
    Pick

    Pelton Wheel flowmeter with high pressure 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMTi
         
    Pick

    Pelton Wheel flowmeter with titanium body, for aggressive applications, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMHa
         
    Pick

    Pelton Wheel flowmeter with Hastelloy body, for aggressive applications, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMDu
         
    Pick

    Pelton Wheel flowmeter with high pressure Duplex body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.006 to 0.1 l/min up to 0.1 to 28 l/min and 33 l/min.
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMPVC
         
    Pick

    Low cost Pelton Wheel flowmeter with PVC body, 1/2" connections providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.1 to 0.25 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMPVC3
         
    Pick

    Low cost Pelton Wheel flowmeter with all-PVC body, no wetted metal parts, 1/2" connections providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.1 to 0.25 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM SPFA
         
    Pick

    Designed for use with medium pressure and temperature applications. Pelton Wheel flowmeter with 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid up to 40 bar pressure.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MMSS
         
    Pick

    Designed for use with high pressure and/or high temperature applications. Pelton Wheel flowmeter with 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MMTi
         
    Pick

    Designed for use in aggressive applications. Pelton Wheel flowmeter with titanium body, providing a pulse output Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM PVC
         
    Pick

    Low cost high flow Pelton Wheel flowmeter with PVC body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM PVC3
         
    Pick

    High flow Pelton Wheel flowmeter with all-PVC body, no metal wetted parts, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    240 Innova-Mass Inline
         
    Pick

    In-Line Multivariable Mass Flow Meter; Hazardous Area Approvals: FM, CSA, & CE, Smart Electronics; In-Line flow body sizes from 1/4" to 8?

    More Information

    Open PDF
    241 Innova-Mass Insertion
         
    Pick

    • Insertion Multivariable Mass Flow Meter;
    • Hazardous Area Approvals: FM, CSA, & CE,
    • Smart Electronics;
    • Insertion probe for line sizes 2" to 72"
    • More Information

    Open PDF
    LF05
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

    • 0 to 30 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    HO Gas
         
    Pick

    Turbine flowmeter with 316 stainless steel body, providing a pulse output, for gas service, 1/4" to 12". Ceramic bearings.

    More Information

    Open PDF
    Wing Nut Gas
         
    Pick

    Wing Nut High Pressure flowmeter with 4130 stainless steel body, providing a pulse output, for gas service. Ceramic bearings. Savage or FMC Wing Nut fitting.

    More Information

    Open PDF
    BG Bellows Gas Meter
         
    Pick

    RITTER bellows-type gas meters are applicable for measuring the volume of flowing inert and dry gases and are particularly effective at high gas flows.

    More Information

    Open PDF
    V125
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

    • 0 to 6,000 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    HF60
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

    • 0 to 3600 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    LMX VTC series
         
    Pick

    Inline Pelton Wheel flowmeter with integral flow straighteners, with display. Suitable for any non abrasive, chemical compatible low viscosity liquid.

    • 0.004 to 0.06 l/min up to 0.1 to 28 l/min and higher.
    • +/-1% reading - linearity.
    • +/-0.2% repeatability over top 90% of range.

    More Information