Flowmeter Products

Filters applied: Media: MediaSeaWater [x]

Displaying 37 results

spacer
LF15
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 90 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
MF30
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 180 litres per hour 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF4
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.

  • 0 to 400 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF8
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.Hazardous area approved as standard.

  • 0 to 800 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LF03
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

  • 0 to 18 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF20
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 1200 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF40
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 2400 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF66
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard. Special order only.

  • 0 to 4000 l/hr 
  • +/-1% reading - linearity.
  • +/-0.25% repeatability.

More Information

Open PDF
V270
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium, PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 16,500 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LMGN
     
Pick

Low cost, plastic bodied Pelton Wheel flowmeter with push-on hose connections, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.006 to 0.1 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMSPFA
         
    Pick

    Pelton Wheel flowmeter with 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid up to 40 bar pressure.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMX series
         
    Pick

    Inline Pelton Wheel flowmeter with integral flow straighteners, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min and higher.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMSS
         
    Pick

    Pelton Wheel flowmeter with high pressure 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMTi
         
    Pick

    Pelton Wheel flowmeter with titanium body, for aggressive applications, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMHa
         
    Pick

    Pelton Wheel flowmeter with Hastelloy body, for aggressive applications, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMDu
         
    Pick

    Pelton Wheel flowmeter with high pressure Duplex body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.006 to 0.1 l/min up to 0.1 to 28 l/min and 33 l/min.
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMPVC
         
    Pick

    Low cost Pelton Wheel flowmeter with PVC body, 1/2" connections providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.1 to 0.25 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMPVC3
         
    Pick

    Low cost Pelton Wheel flowmeter with all-PVC body, no wetted metal parts, 1/2" connections providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.1 to 0.25 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM SPFA
         
    Pick

    Designed for use with medium pressure and temperature applications. Pelton Wheel flowmeter with 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid up to 40 bar pressure.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MMSS
         
    Pick

    Designed for use with high pressure and/or high temperature applications. Pelton Wheel flowmeter with 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MMTi
         
    Pick

    Designed for use in aggressive applications. Pelton Wheel flowmeter with titanium body, providing a pulse output Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM PVC
         
    Pick

    Low cost high flow Pelton Wheel flowmeter with PVC body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM PVC3
         
    Pick

    High flow Pelton Wheel flowmeter with all-PVC body, no metal wetted parts, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    205 Innova-Sonic
         
    Pick

    Ultrasonic flowmeter system incorporating digital signal processing. Innova-Sonic offers a low power consumption, clear display and user friendly menu selection.

    More Information

    Open PDF
    206 Innova-Sonic
         
    Pick

    In-line Ultrasonic flowmeter system incorporating digital signal processing. Innova-Sonic offers a low power consumption, clear display and user friendly menu selection. 1" to 10".

    More Information

    Open PDF
    210 Innova-Sonic
         
    Pick

    Fully field portable ultrasonic system complete with spare battery pack, non-invasive clamp-on transducers, mounting hardware and a unique PalmOne Personal Digital Assistant (PDA) interface for a totally self-contained measurement package.

    More Information

    Open PDF
    240 Innova-Mass Inline
         
    Pick

    In-Line Multivariable Mass Flow Meter; Hazardous Area Approvals: FM, CSA, & CE, Smart Electronics; In-Line flow body sizes from 1/4" to 8?

    More Information

    Open PDF
    241 Innova-Mass Insertion
         
    Pick

    • Insertion Multivariable Mass Flow Meter;
    • Hazardous Area Approvals: FM, CSA, & CE,
    • Smart Electronics;
    • Insertion probe for line sizes 2" to 72"
    • More Information

    Open PDF
    LF05
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

    • 0 to 30 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    HO Liquid
         
    Pick

    Turbine flowmeter with 316 stainless steel body, providing a pulse output, for liquid service, 1/4" to 12". Ceramic bearings.

    More Information

    Open PDF
    HO API
         
    Pick

    Turbine flowmeter with 316 stainless steel body, providing a pulse output, for liquid service, 3/4" to 12". Ceramic bearings.

    More Information

    Open PDF
    HO Sanitary
         
    Pick

    Turbine flowmeter with 316 stainless steel body, providing a pulse output, for liquid service, 1/4" to 3". Ceramic bearings. 3-A Sanitary standard 28-03.

    More Information

    Open PDF
    HO Autoclave
         
    Pick

    Turbine flowmeter with 316 stainless steel body, providing a pulse output, for liquid service, 1/4" to 3/4". Ceramic bearings. Autoclave male thread.

    More Information

    Open PDF
    Wing Nut Liquid
         
    Pick

    Wing Nut High Pressure flowmeter with 4130 stainless steel body, providing a pulse output, for liquid service. Ceramic bearings. Savage or FMC Wing Nut fitting

    More Information

    Open PDF
    V125
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

    • 0 to 6,000 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    HF60
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

    • 0 to 3600 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    LMX VTC series
         
    Pick

    Inline Pelton Wheel flowmeter with integral flow straighteners, with display. Suitable for any non abrasive, chemical compatible low viscosity liquid.

    • 0.004 to 0.06 l/min up to 0.1 to 28 l/min and higher.
    • +/-1% reading - linearity.
    • +/-0.2% repeatability over top 90% of range.

    More Information

    Open PDF