Flowmeter Products

Filters applied: Flowmerer Type: TypeRotaryPiston [x]

Displaying 12 results

spacer
LF15
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 90 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
MF30
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 180 litres per hour 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF4
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.

  • 0 to 400 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF8
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.Hazardous area approved as standard.

  • 0 to 800 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LF03
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

  • 0 to 18 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF20
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 1200 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF40
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 2400 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF66
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard. Special order only.

  • 0 to 4000 l/hr 
  • +/-1% reading - linearity.
  • +/-0.25% repeatability.

More Information

Open PDF
V270
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium, PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 16,500 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LF05
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

  • 0 to 30 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
V125
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 6,000 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF60
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 3600 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF