Flowmeter Products

Filters applied: endfit: EndFitting04 [x]

Displaying 22 results

spacer
LF15
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 90 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
MF30
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 180 litres per hour 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF4
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.

  • 0 to 400 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
VFF8
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range.Hazardous area approved as standard.

  • 0 to 800 litres per hour
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LF03
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

  • 0 to 18 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF20
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 1200 l/hr
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF40
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 2400 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
HF66
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard. Special order only.

  • 0 to 4000 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
V270
     
Pick

Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium, PVD coated rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

  • 0 to 16,500 l/hr 
  • +/-0.5% reading - linearity.
  • +/-0.1% repeatability.

More Information

Open PDF
LMSS
     
Pick

Pelton Wheel flowmeter with high pressure 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMTi
         
    Pick

    Pelton Wheel flowmeter with titanium body, for aggressive applications, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMHa
         
    Pick

    Pelton Wheel flowmeter with Hastelloy body, for aggressive applications, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.004 to 0.06 l/min up to 0.1 to 28 l/min.
  • +/-2% reading - linearity. [003 and 005 linearisation required]
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMDu
         
    Pick

    Pelton Wheel flowmeter with high pressure Duplex body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 0.006 to 0.1 l/min up to 0.1 to 28 l/min and 33 l/min.
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    LMXPVC
         
    Pick

    Low cost Pelton Wheel flowmeter with PVC body, 1/2" connections providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

    • 0.1 to 0.25 l/min up to 0.1 to 28 l/min.
    • +/-2% reading - linearity. [003 and 005 linearisation required]
    • +/-0.2% repeatability over top 90% of range.

    More Information

    Open PDF
    LMXPVC3
         
    Pick

    Low cost Pelton Wheel flowmeter with all-PVC body, no wetted metal parts, 1/2" connections providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

    • 0.1 to 0.25 l/min up to 0.1 to 28 l/min.
    • +/-2% reading - linearity. [003 and 005 linearisation required]
    • +/-0.2% repeatability over top 90% of range.

    More Information

    Open PDF
    MM SPFA
         
    Pick

    Designed for use with medium pressure and temperature applications. Pelton Wheel flowmeter with 316 stainless steel body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid up to 40 bar pressure.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM PVC
         
    Pick

    Low cost high flow Pelton Wheel flowmeter with PVC body, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    MM PVC3
         
    Pick

    High flow Pelton Wheel flowmeter with all-PVC body, no metal wetted parts, providing a pulse output. Suitable for any non abrasive, chemical compatible low viscosity liquid.

  • 1 to 65 l/min up to 10 to 500 l/min. (up to 300 to 5500 l/min by special order)
  • +/-2% reading - linearity.
  • +/-0.2% repeatability over top 90% of range.
  • More Information

    Open PDF
    780S-UHP Ultra High Purity
         
    Pick

    Ultra-High-Purity In-Line mass flow meter; NEMA 4X and Hazardous Area, Approvals: FM, ATEX, CSA, EEx, PED, CE, Cenelec; Smart electronics; flow body sizes from 3/8? to 6?.

    More Information

    Open PDF
    LF05
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor. Hazardous area approved as standard.

    • 0 to 30 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    V125
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

    • 0 to 6,000 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF
    HF60
         
    Pick

    Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. PVD coated titanium rotor dependent on pressure and flow rate range. Hazardous area approved as standard.

    • 0 to 3600 l/hr
    • +/-0.5% reading - linearity.
    • +/-0.1% repeatability.

    More Information

    Open PDF